INSTRUCTION MANUAL
DUAL DISPLAY L C R METER
Model : DE-5000
Thank you for purchasing our products. Please read this
instruction manual before using the meter and keep it
properly for contingent use.
- 1 -
Table of Contents
I. Introduction…………………………................. 03
II. Measuring Principle Introduction………… 04 ~ 07
III. Panel Illustration………................................ 08 ~ 10
IV. LCD Display Illustration………………..……… 11 ~ 12
V. Operation Instructions………………..……….. 13 ~ 34
1. Power ON/OFF …………………….…………. 13 ~ 14
2. CAL ……………………………………………. 15 ~ 17
3. LCR AUTO …………………………………….. 18 ~ 20
4. Inductance / Capacitance / Resistance
Measurement…………………………………. 20 ~ 21
5. FREQ ………………………………………….. 22 ~ 23
6. Backlight ………………………………………. 23
7. SORTING / SETUP / ENTER ……………..... 23 ~ 25
8. PC ……………………………………………… 26
9. D/Q/ESR/ș …………………………………….. 27 ~ 28
10. SER/PAL ………………………………………. 29
11. REL ……………………………………………. 30 ~ 31
12. HOLD …………………………………………... 32
VI. Replacing Batteries……………..……………… 33
VII. General Specification……………..…………… 34
VIII. Electrical Specification……………..…………. 35 ~36
Vista de página 0
1 2 3 4 5 6 ... 18 19

Resumo do Conteúdo

Página 1 - DUAL DISPLAY L C R METER

INSTRUCTION MANUAL DUAL DISPLAY L C R METER Model : DE-5000 Thank you for purchasing our products. Please read this instruction manual before using

Página 2 - I. Introduction

- 18 - 3. LCR AUTO y The “LCR AUTO” key selects the primary parameter measurement function. Each press of the key will select either Auto-LCR mode, A

Página 3 - Measurement mode

- 20 - If C < 5pF. The parameter on sub-display is Rp. *2: When LCR Auto mode is active, the secondary parameter will show the equivalent resi

Página 4 - Equivalent circuit

- 22 - 5. FREQ y The “FREQ” key selects the testing frequency. Each press of the key will select either 1kHz, 10 kHz, 100kHz, 100Hz or 120Hz, total 5

Página 5 - Panel Illustration

- 24 - y The primary display will show PASS or FAIL which based on whether the impedance measured exceeds tolerance range. The secondary display will

Página 6

- 26 - IR to USB caseUSB socket 8. PC (IR to USB case is optionel. Measuring data can be transferred to PC with it. ) y Snap on IR to USB case and

Página 7 - IV. Operation Instructions

- 28 - Secondary display parameter is ș. Press “ D/Q/ESR/ș ” key Back to parameter D measurement Ɣ D/Q/ESR/ș setting is not applied to resistance m

Página 8

- 30 - 11. REL y In LCR Auto mode, this key has no function. y Press the “REL” key to enter relative mode. The value on the display will be stored

Página 9

- 32 - 12. HOLD y Press the “HOLD” key to freeze the reading on the primary display and “HOLD” will appear. y In the Hold mode, only key and PC

Página 10

- 34 - VI. General Specification Item Dual Display L C R Meter Parameters Measured Ls/ Lp/ Cs/ Cp/ Rs/ R p/ D/ Q/ Ĭ/ ESR L C R auto selection Measurin

Página 11

- 36 - Ϯʳ Inductance (Parallel / Series mode). Range Resolution 100/120Hz 1kHz 10kHz 100kHz 20.000ȝH 0.001ȝH ņ ņ ņ 2.5%+5* 200.00ȝH 0.01ȝH ņ ņ 1.

Página 12

- 2 - Electrical Symbol Risk of Danger. Important information. See Manual. AC/DC power adaptor input polarity Current battery capacity indicator

Página 13

- 4 - II. Measuring Principle Introduction Impedance parameter introduction 䎷䏋䏈䎃 䏌䏐䏓䏈䏇䏄䏑䏆䏈䎃 䏆䏒䏑䏖䏌䏖䏗䏖䎃 䏒䏉䎃 䏕䏈䏖䏌䏖䏗䏄䏑䏆䏈䎃 䎋䏕䏈䏄䏏䎃 䏓䏄䏕䏗䎌䎃 䏄䏑䏇䎃 䏕䏈䏄䏆䏗䏄䏑䏆䏈䎃

Página 14 - USB socket

- 6 - There are two factors to provide the ratio of real part and imaginary part. Usually the quality factor Q is used for inductance measurement and

Página 15

- 8 - Panel Illustration Front panel Side “GUARD” provides shield for DUT ( device under test ), improvised test leads or equipments situated at plac

Página 16

- 10 - 1. LCD display 2. POWER To power on/off the instrument 3. LCR AUTO LCR auto mode, Inductance, Capacitance, Resistance and DC resistan

Página 17 - V. Replacing Batteries

- 12 - 14. D/Q/ș Dissipation factor, Quality factor or Phase angle is active for L/C measurement mode 15. Rp AC Resistance in parallel mode is acti

Página 18 - VI. General Specification

- 14 - y The default setting is LCR auto mode at test frequency 1kHz. y Battery condition is detected every second and displayed. suggests batt

Página 19 - HCA500000-00020

- 16 - y If calibration is completed, PASS or FAIL appears on the primary display. y If both calibrations are passed, press ”CAL” key again to sto